Energy Glossary

This glossary provides an overview of terms frequently used in the energy sector. The information is meant to be a guide for decision-makers and the public to better decipher these terms, which are often used in hearings, presentations, and other public fora without additional background or context. The terms provided in this glossary are presented by sector and may refer to definitions in other sectors. Keep this glossary handy to better understand wonky energy conversations.
If you have questions about this content or suggestions for additions, please contact Rebecca Rehr, Maryland’s Director of Climate Policy & Justice at info@mdlcv.org.

Electric Grid & Utility Operations
Renewable Energy & Demand Side Management
Utility Regulation & Markets
Emerging Technologies & Policy Concepts

Electric Grid and Utility Operations

  • Behind-the-Meter (BTM): Usually smaller energy resources that are located on the customer side of an electric utility’s meter and primarily used to serve or manage that customer’s energy needs. Depending on the technology, these resources may generate or store electricity, reduce or shift energy consumption, provide backup power, and sometimes export electricity to the grid. Examples include rooftop solar, battery storage, backup generators, programmable thermostats and other controllable equipment, and geothermal heat pumps.
  • Co-located/ Dedicated Generation: A power plant or other electricity generating resource that is built at or near a large energy user, such as a data center, and is intended to serve or offset that user’s energy needs. Co-located generation is often used as part of a “bring your own energy” model, in which the customer supplies some or all of its needed electricity rather than relying on the existing utility grid. These resources may or may not be BTM, depending on their configuration and point of interconnection, as well as any specific rules for large load users bringing their own energy.
  • Distributed Energy Resources (DERs): Energy resources that generate, store, or manage electricity on the distribution grid. All BTM energy resources are DERs, but not all DERs are located BTM on the customer’s side of the utility meter. For example, residential rooftop solar is a DER that is BTM, while a community solar project that households subscribe to is a DER that is in front-of-the-meter (defined below).
  • Distributed Generation (DG): Electricity produced by systems connected directly to the distribution grid or located behind a customer’s meter. DG refers to the electricity-generating subset of DERs and includes technologies such as rooftop solar, community solar, small wind, and on-site generators. While much smaller than traditional, centralized power plants, DG resources reduce reliance on long distance transmission and can defer the need for additional, costly grid infrastructure because they are located at or near where electricity is used.
  • Distribution Grid: The local network of power lines, poles, transformers, and substations that deliver electricity from the larger transmission systems directly to Maryland homes and businesses. The electric grid can be compared to a road network: If the transmission system (defined below) functions as an interstate highway, while the distribution grid is the network of local roads after you take the exit. The transmission system is overseen by the regional grid operator, PJM, and the distribution system is overseen by the state’s utilities.
  • Electric Distribution Company (EDC): Synonymous with “utility,” specifically referring to the local utilities that deliver electricity.
  • Front-of-the-Meter (FTM): Energy resources located on the utility side of the customer meter and connected directly to the distribution grid or transmission system. These resources supply electricity or grid services to wholesale markets, utilities, or multiple utility customers. Utility-scale solar projects, battery energy storage systems, and wind farms are examples of FTM resources.
  • Grid Reliability: The electric system’s ability to consistently deliver safe, dependable power while minimizing outages.
  • Grid Services: An umbrella term for a range of functions that support the grid; functions that keep the electric grid reliable, balanced, and cost effective. Grid services can support both the transmission and distribution grid. Examples include reducing demand during peak periods, keeping voltage and frequency stable, and relieving congestion on local lines. NOTE: Some entities (e.g. PJM) may have a more specific definition, so the meaning can depend on the context in which the term is used.
  • Grid Utilization: A measure of how much of the electric grid’s available capacity is actually being used to move and deliver electricity. Higher grid utilization generally means existing transmission and distribution infrastructure is being used more fully, while lower utilization can indicate that parts of the grid are underused. Very high utilization can also indicate congestion or limited remaining capacity at certain times or locations.
  • Integrated Resource Planning (IRP): A long-term planning process primarily used in vertically integrated, traditionally regulated electricity markets, where utilities are responsible for planning and procuring the resources needed to cost-effectively meet future customer demand while maintaining reliable service. IRPs evaluate different combinations of energy resources, including fossil fuel power plants, nuclear energy, renewable energy, demand-side management, and energy storage, while considering costs, reliability, environmental impacts, and public policy goals. Maryland does not utilize an IRP process, although the recent creation of the state’s Strategic Energy Planning Office (SEPO) is meant to oversee the function of creating a state energy plan.
  • Interconnection: The process of connecting new electricity generation or energy storage resources to the electric grid. The interconnecting utility, PJM, or both review interconnection applications to ensure the new system can operate safely and reliably without disrupting electric service. Depending on the size and complexity of the project, this review often requires engineering studies or grid upgrades financed by the owner of the system before the system can begin operating.
  • Levelized Cost of Energy (LCOE): The average cost of producing one unit of electricity over a generating system’s expected lifetime. It accounts for costs such as construction, financing, fuel, operations, maintenance, and expected electricity production, allowing different generation technologies to be compared on a consistent dollars-per-megawatt-hour basis. LCOE is a vetted, and widely used metric employed by institutions like Lazard in their annual Levelized Cost of Energy+ report.
  • Levelized Avoided Cost of Energy (LACE): A measure of the value that an electricity generating resource provides to the power system over its lifetime. It estimates the cost the grid would otherwise incur to produce the same electricity and capacity if that resource were not built, expressed as an average cost per unit of electricity. LACE is often compared with the LCOE: if a resource’s LACE is higher than its LCOE, the value it provides to the grid is greater than its estimated cost.
  • Levelized Full System Cost of Electricity (LFSCOE): A metric that estimates the cost of serving an entire electricity system using only one type of generation, supplemented by energy storage. Unlike traditional levelized cost measures, it assumes that the selected technology replaces all other generation resources and must meet demand around the clock. LFSCOE is a non-mainstream metric based on an unrealistic single technology scenario that does not reflect how PJM and other wholesale markets dispatch a diverse generation fleet.
  • Net Energy Metering (NEM): A billing arrangement that allows utility customers with on-site generation to offset electricity purchased from the grid with electricity exported by their system during the same billing period. Under Maryland’s existing NEM program, exported electricity offsets grid consumption on a 1:1 kilowatt-hour basis, meaning these customers are credited by the utility for the electricity they generate at the same retail rate they are charged for electricity. Any unused excess generation may be carried forward as a credit to offset electricity consumed on later utility billing periods. Maryland also uses NEM-based bill credits for community solar subscribers. The existing program remains available until the earlier of July 1, 2027, or the statewide total reaching 3 gigawatts, with limited exceptions for certain community solar projects.Following passage of the Utility RELIEF Act of 2026, the Public Service Commission (PSC) is considering changes to Maryland’s NEM rules, including the transition to a successor program, grandfathering requirements, statewide capacity tracking, time-varying rates, and aggregate net metering. This rulemaking is also examining compensation for exported electricity, ratepayer costs and benefits, and the treatment of different generation technologies and market segments.
  • Peak Demand: The highest level of electricity use during a specified period, often occurring during very hot summer afternoons or cold winter mornings. Because the electric system must have enough generation and grid capacity available to meet this maximum demand, peak demand significantly influences electricity costs, resource adequacy requirements, and long-term infrastructure planning. DERs that reduce or shift electricity use during peak periods can thus support grid reliability, lower electricity costs, and defer infrastructure investments. PJM is responsible for ensuring the grid can meet peak demand. Their peak demand forecasting has been affected by massive data center demand projections. In 2024, growing electricity demand, particularly from data centers, combined with changes to market rules, contributed to an 800% increase in PJM’s capacity auction prices, which led to rising electricity bills for customers across the region.
  • PJM Interconnection: The regional organization responsible for operating the high voltage transmission system and the wholesale electricity market in 13 states and the District of Columbia. PJM controls the process for determining when and how new large generation resources can connect to the transmission system. Historically, that process was a major bottleneck: PJM accumulated a large backlog of proposed generation projects and some resources have faced years of studies, repeated delays, and uncertainty about the cost of grid upgrades, before the resource can interconnect and begin operating. PJM has since overhauled its interconnection process, but lengthy and complex interconnection remains a significant challenge to bringing new generation online. PJM’s voting structure gives significant influence to utilities, electricity generators, transmission owners, and other energy market participants. These entities collectively represent four of PJM’s five voting sectors, while end-use customers, including consumer advocates, share the remaining sector. State utility regulators can participate in PJM’s stakeholder process but do not have voting rights. This means that the companies participating in PJM’s electricity markets also have substantial influence over the rules governing those markets.. The Federal Regulatory Energy Commission (FERC) oversees PJM, and is considering governance reform to address some of these issues.
  • Power Purchase Agreement (PPA): A contract under which a customer, utility, or other buyer agrees to purchase electricity from an energy project at specified prices and terms for a set period. PPAs provide the project owner with a predictable revenue stream and allow the buyer to secure electricity without owning the generating system.
  • Resource Adequacy: Having enough available energy resources to meet customer demand during periods with the highest electricity use (see Peak Demand).
  • Transmission System (sometimes referred to as “The Grid” or “Transmission Grid”): The network of high voltage power lines, substations, transformers, and related equipment that moves large amounts of electricity over long distances between large power plants and local distribution grids. Regional transmission organizations such as PJM coordinate transmission operations and planning across multiple states to maintain reliability.
  • Virtual Power Plant: A network of DERs coordinated through software to operate collectively and provide grid services comparable to those of a traditional power plant. VPPs can reduce or shift electricity demand and supply electricity to the grid when needed. Typically, VPPs are more dynamic and can include generation and storage assets (e.g. a home battery or solar system), as well as tools that reduce load (e.g. demand side management).
Back to Top

Renewable Energy and Demand Side Management

  • Alternative Compliance Payment (ACP): A fee that a Maryland electricity supplier pays for each megawatt-hour by which it falls short of the state’s Renewable Portfolio Standard (RPS), instead of retiring the required Renewable Energy Credit (REC) or Solar Renewable Energy Credit (SREC). ACPs are deposited into the Maryland Strategic Energy Investment Fund and help place an effective ceiling on REC prices because suppliers may pay the ACP when credits are unavailable or more expensive. In 2024, the Maryland PSC recorded $365 million in ACP costs, which are recovered from customers through electricity supply charges.
  • Beneficial Electrification: The replacement of fossil fuel technologies with electric alternatives when doing so lowers overall costs and improves efficiency.
  • Demand Response: Programs or market arrangements that reward customers for reducing or shifting their electricity use during periods of high demand, high prices, or grid stress. Participants may respond manually or through automated controls, helping reduce peak demand and avoid the need to operate or build additional generation or grid infrastructure. Demand response is an example of demand side management.
  • Energy Efficiency: Using less energy to provide the same or better level of service, comfort, or productivity. Examples include efficient lighting and appliances, improved insulation, high efficiency heating and cooling systems, and industrial equipment that reduces energy waste. Energy efficiency is also a type of demand side management.
  • Energy Storage Technologies: Absorb electricity or another form of energy and release it later when needed. Batteries are the most common form of modern electric storage, but other examples include pumped hydropower, thermal storage, and flywheels. Storage can shift electricity from lower demand periods to higher demand periods, provide backup power, reduce peak demand, and support grid reliability.
  • Energy Storage Market Segments
    • Behind-the-Meter (BTM) Energy Storage: A storage system located BTM that can provide backup power, reduce electricity purchases during high cost periods, manage peak demand, or store electricity produced by on-site generation such as rooftop solar. They may also participate in utility programs or VPPs that combine multiple customer owned resources to provide grid services.
    • Distribution-Connected Energy Storage: A Front of the Meter (FTM) storage system connected directly to the distribution grid. These projects can relieve local grid constraints, support distribution-system reliability, complement distributed generation such as community solar, and provide energy, capacity, or other grid services.
    • Utility Scale/ Transmission-Connected Energy Storage: A large Front of the Meter (FTM) storage system connected to the high voltage transmission system and operated primarily to serve the broader electric grid. These projects may participate in wholesale energy, capacity, and ancillary services markets, reduce transmission congestion, integrate large amounts of renewable generation, and support regional reliability.
    • Stand-Alone Energy Storage: A storage system developed and operated independently of a specific generation facility. It charges from the electric grid and can be located where its services are most valuable, such as near constrained substations, large loads, or transmission facilities.
    • Generation-Coupled Energy Storage: A storage system paired with a generation resource so that electricity produced by the generator can be stored and delivered later (e.g. solar + storage). Coupled storage can smooth variable output, provide more predictable delivery of electricity, and shift electricity generated from renewable energy resources to higher demand periods. Depending on the project’s design and interconnection agreement, the storage system may charge only from the paired generator or may also charge from the grid.
  • Renewable Energy Credit (REC): A tradable certificate representing the renewable energy attributes of one megawatt-hour of electricity generated by an eligible renewable energy resource. In Maryland, electricity suppliers purchase and retire RECs from Tier 1 and Tier 2 resources to meet Maryland’s
  • Renewable Portfolio Standard (RPS): The REC may be bought and sold separately from the electricity itself.
  • Solar Renewable Energy Credit (SREC): A type of REC created by eligible solar generation at the rate of one SREC for each megawatt-hour produced. Electricity suppliers use SRECs to satisfy the solar specific portion, also known as the “solar carve out,” of Maryland’s RPS, creating an additional source of revenue for whoever owns the credit.
  • Solar Technologies: Convert sunlight into electricity using photovoltaic panels or capture the sun’s heat for thermal energy applications. Solar generation has no fuel cost, and although output varies with weather and time of day, the energy generated follows predictable daily and seasonal patterns. Solar technologies are commonly grouped into market segments based on system size, location, and customer type.
  • Solar Market Segments
    • Behind-the-Meter (BTM) Solar: A solar system located on a customer’s property and used primarily to offset electricity consumed by that customer. It may serve a home, business, farm, institution, or industrial facility, and any excess electricity is exported to the grid under applicable Net Energy Metering (NEM) rules.
    • Aggregate Net Energy Metering (ANEM) Solar: A solar arrangement that allows a single customer to allocate excess generation credits among multiple electric meters or accounts associated with that customer. In Maryland, ANEM is available to agricultural customers, nonprofit organizations, municipal and county governments and their affiliated organizations, state government agencies, and higher education institutions. Unlike community solar, it combines accounts associated with a single eligible customer.
    • Community Solar: A Front of the meter (FTM) solar system connected to the distribution grid that allows multiple customers to subscribe to a share of the system’s output and receive credits on their electric bills without having to install solar on their own properties. Under current Maryland law, a community solar system must be located in the same electric utility service territory as its subscribers, have at least two subscribers, and may not exceed 5 megawatts of capacity. Community solar projects are commonly ground-mounted but may also be located on rooftops. Maryland’s law requires at least 40% of power produced by a community solar project to go to low-to-moderate income households, and also guarantees financial savings for all residential community solar subscribers.
    • Utility Scale Solar: A large, usually ground-mounted, front of the meter (FTM) solar system that is normally connected to the transmission system and supplies electricity to the broader electric grid. These projects sell electricity through wholesale market participation, a power purchase agreement (PPA), or another market arrangement.
  • Tier 1 Renewable Sources: The primary category of energy resources eligible under Maryland’s Renewable Portfolio Standard (RPS). Tier 1 includes energy resources from solar, wind, methane, geothermal, ocean energy, certain fuel cells, small hydroelectric facilities, poultry litter, thermal biomass, and wastewater used for heating or cooling.
  • Tier 2 Renewable Sources: A separate category under Maryland’s Renewable Portfolio Standard (RPS) consisting of hydroelectric power other than pumped storage generation. Maryland requires electricity suppliers to meet a 2.5% Tier 2 requirement, although Tier 1 renewable energy credits may also be used to satisfy that requirement.
Back to Top

Utility Regulation and Markets

  • Ancillary Services: The specialized services that keep the electric grid operating safely and reliably, including balancing electricity supply and demand, maintaining the grid’s frequency and voltage, and providing backup power when unexpected events occur. Traditionally supplied by large power plants, ancillary services are increasingly provided by Distributed Energy Resources (DERs) and other advanced technologies.
  • Capacity Markets: Organized electricity markets that pay power plants, energy storage, demand response, and energy efficiency resources to help meet future electricity demand, even if they are not producing electricity every day. In Maryland, the capacity market is administered by PJM through its Reliability Pricing Model. Its purpose is to help ensure the power system has enough reliable capacity to meet peak demand, reduce the risk of shortages, and maintain reliability during periods of high system stress. The prices set through PJM’s capacity auctions ultimately affect the cost of electricity paid by Maryland customers.
  • Competitive Electricity Market (aka Restructured or Deregulated Market): An electricity market in which customers may choose their electricity supplier instead of being required to buy power from their local utility. The utility still owns and operates the distribution system and delivers the electricity to customers, while competitive suppliers sell the electricity itself. Customers who do not select a supplier receive utility provided default service. In these markets, electricity prices are determined through competition rather than by regulators alone. Maryland has a deregulated electricity market.
  • Cost Recovery: The process by which utilities recover the reasonable costs of providing electric service through customer rates approved by the Maryland Public Service Commission (PSC), including investments in power lines, substations, maintenance, and other infrastructure needed to operate the electric system.
  • Default Service Rate: The price charged by a utility for electricity supply when a customer does not independently shop for a competitive electricity supplier. In Maryland, the utility purchases this electricity on customers’ behalf and passes the approved supply costs through without earning a profit on the energy itself.
  • Rate Design: The process of determining how utilities charge customers for electricity. Electric rates include a combination of fixed charges, charges based on the amount of electricity used, and, for some customers, charges based on their highest level of electricity demand. Rate design that prioritizes ratepayer needs seeks to recover utility costs while encouraging efficient energy use and maintaining fair treatment among different customer groups.
  • Standard Offer of Service: The price charged by a utility for electricity supply when a customer does not independently shop for a competitive electricity supplier. The utility purchases this electricity on customers’ behalf and passes the approved supply costs through to customers, along with approved administrative charges that may include a utility profit.
Back to Top

Emerging Technologies and Policy Concepts

  • Advanced Transmission Technologies (ATTs): Technologies that increase the capacity, efficiency, reliability, or flexibility of the existing high voltage transmission system. Examples include advanced conductors, dynamic line ratings, power flow control devices, and improved monitoring systems. By allowing more electricity to move over existing infrastructure, these technologies accelerate the interconnection of new sources of generation and defer, reduce, or sometimes avoid the need to build costly new transmission lines.
  • Flexible Interconnection: Allowing a generation source to connect to the grid subject to agreed operating limits, rather than requiring the grid to accommodate the project’s full output at all times. For example, a utility may temporarily limit a solar or battery system’s exports when local grid capacity is constrained. This approach reduces or avoids costly grid upgrades needed to interconnect the system, thus allowing projects to begin producing electricity more quickly. The customer assumes some risk that the system’s output may occasionally be restricted. Maryland utilities have begun using flexible interconnection methods to accommodate more Distributed Energy Resources (DERs) on the distribution grid.
  • Grid Enhancing Technologies (GETs): Technologies that help grid operators use existing electric infrastructure more efficiently, safely, and reliably. The term is commonly used interchangeably with ATTs but GETs are also applied to improving the operation of the local distribution grid. Distribution grid improvements include advanced sensors, smart meters, automated controls, communications systems, cybersecurity measures, and advanced distribution management systems. By increasing usable distribution grid capacity and reducing congestion, these technologies can connect Distributed Energy Resources (DERs) more quickly and defer or avoid costly infrastructure upgrades.
  • Grid Modernization: An umbrella term encompassing efforts to upgrade the transmission system or distribution grid with new technologies and operating practices that improve reliability, efficiency, resilience, security, and the ability to cost effectively integrate new sources of electricity generation. Simply put, grid modernization refers to “getting more out of the grid we have.”
  • Microgrids: Small, self-contained electric networks that can generate, store, and distribute electricity to a specific group of buildings or facilities, such as a hospital, military base, university campus, or neighborhood. A microgrid operates while connected to the larger electric grid but can disconnect and continue providing power during outages, improving resilience and reliability.
  • Vehicle-to-Grid Technology (V2G): Allows electric vehicles to both charge from the distribution grid and send electricity back to the grid when needed. By using the vehicle’s battery as a temporary energy resource, V2G can help reduce peak demand, improve grid reliability, and support the integration of renewable energy. Vehicle owners may also receive financial compensation for participating in V2G programs.
Back to Top

This glossary was prepared by Labora Strategies, LLC for the Maryland League of Conservation Voters Education Fund. Labora Strategies is led by Leah Meredith, a Maryland-based energy policy and programs professional with more than a decade of experience working across the PJM and MISO markets. Her background includes designing and implementing policies and utility programs focused on affordability, service delivery, and grid reliability in partnership with utilities, public entities, advocacy organizations, and independent power producers.